Res. Agr. Eng., 2007, 53(4):121-125 | DOI: 10.17221/1954-RAE
Milking-related changes of teat temperature caused by various milking machines
- 1 Research Institute of Agricultural Engineering, Prague-Ruzyně, Czech Republic
- 2 Leibnitz-Institute for Agricultural Engineering e.V., Potsdam, Germany
The aim of the performed work was to verify the hypothesis that different milking equipments have different influence on the blood circulation in the milk gland during milking. This influence was investigated by measuring the surface temperature of the milk gland using thermography. The influence was monitored of 5 different milking units in total, out of them 2 AMS, on the teat temperature which was scanned and evaluated in the teat tip centre and on the teat base at the same time with the surface temperature of the udder, always at the instant closely preceding the cluster application and then after its removal. It was ascertained that the average temperature of the teat tip after milking was increased in comparison with the temperature before milking practically in all the milking units monitored. At the same time, the average temperature of the teat tip in the milking equipment in parlours increased by about 1.7°C-2.7°C (6.1%-9.0%) as compared to the temperature before milking. At milking in AMS, the temperature rise of the teat tip was smaller and reached only 0.9°C-1.7°C (2.9%-6.0%). At the same time, the temperature of other parts of the milk gland grew commensurately. It was also found that differences exist between different milking units with respect to their influence on the temperature fluctuation of the milk gland. From the monitoring performed up to now and from the results acquired it is possible to apprehend that the monitoring of the teat temperature before and after milking with the help of thermography can become an indicator of the working quality of the milking equipment and its influence on the milk gland. The confirmation of this hypothesis requires, however, further detailed and extensive measuring to be carried out.
Keywords: teat temperature; milking machine; infrared thermography
Published: December 31, 2007 Show citation
References
- Barth K. (2001): Investigations using infrared-thermographs to monitor udder health in cow. In: Bau und Umwelt in der landwirtschaftlichen Nutztierhaltung, March 6-7, 2001, Hohenheim, 224-228.
- Bramly A.J., Dodd F.H., Mein G.A. (1992): Machine Milking and Lactation. Insight Books, Vermont.
- Isaksson A., Lind O. (1994): Milking related changes in the surface temperature of the bovine teat skin. Acta Veterinaria Scandinavica, 35: 435-438. O. (2000): Comparison of rubber liners by means of temperature states of teats. Research in Agricultural Engineering, 46: 104-107.
Go to original source...
Go to PubMed...
- Ordolff D. (2000): Surface temperatures of udder and teats for conventional and automatic milking methods. Kieler Milchwirtschaftliche Forschungsberichte, 52: 5-10.
- Paulrund C.O., Clausen S., Andersen P.E., Rasmussen M.D. (2005): Infrared termography and ultrasonography to indirectly monitor the influence of liner type and overmilking on teat tissue recovery. Acta Veterinaria Scandinavica, 46: 137-147
Go to original source...
Go to PubMed...
- Rabold K. (1974): Biotechnik der Milchgewinnug. Verlag Eugen Ulmer, Stuttgart.
- Weber W. (1977): Einflüsse verschiedener Melkparametr auf die Milchgabe. In: Probleme der moderne Melktechnik. KTBL-Schrift, 217: 11-15.
- Worstorf H. (1994): Melktechnik - Der aktuelle Stand über Melken, Milch und Melkmaschinen. Landwitschaftsverlag GmbH, Münster.
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.